Scanning / copying applications: security levels, ports and protocols used by the Océ systems
Application /Function‐
ality
System Supported security levels (x) and
open port
Port used on the
controller: proto‐
col
N* M* M-H* H*
Scan to File Remote
SMB
Océ PlotWave
750 /
PlotWave 900
R2.x
x -
Scan to File Remote
FTP
Océ PlotWave
750 /
PlotWave 900
R2.x
x
x
(1)
x
(1)
x
(1)
-
Scan data retrieval by
FTP
Océ PlotWave
750 /
PlotWave 900
R2.x
x
TCP 21
TCP
4242
x
(2)
TCP 21
TCP 21: FTP
TCP 4242: FTP
(3)
Scan data retrieval
from Smart Inbox
(Scans)
Océ PlotWave
750 /
PlotWave 900
R2.x
x
TCP 80
x
TCP 80
TCP 80: HTTP
Scan data retrieval
from Smart Inbox
(Scans) over SSL
Océ PlotWave
750 /
PlotWave 900
R2.x
x
TCP 443
x
TCP 443
x
TCP
443
x
TCP
443
TCP 443: HTTPS
Océ Matrix Logic Océ PlotWave
750 /
PlotWave 900
R2.x
x
TCP 80
TCP 443
x
TCP 80
TCP 443
x
TCP
443
x
TCP
443
TCP 80: HTTP
TCP 443: HTTPS
Notes:
* Levels: N: Normal - M: Medium - M-H: Medium/High - H: High
(1)
FTP passive mode only: the FTP server on the remote workstation must support FTP passive
mode
(2)
FTP active mode only
(3)
Data channel for FTP passive mode
Control management: security levels, ports and protocols used by the Océ systems
Application /Func‐
tionality
System Supported security levels (x)
and open port
Port used on the
controller: pro‐
tocol
N* M* M-H* H*
PING Océ PlotWave 750 /
PlotWave 900 R2.x
x x x x ICMP
4
Applications, protocols and ports used on the Océ PlotWave 750 and the Océ PlotWave 900 R2.x systems