Password for Can be changed by Stored in the back up set*
Remote Service Proxy authenti-
cation user
System administrator or Power
user
Yes, stored encrypted.
* When you make a back up set of your system settings using the 'Save Set' feature in Océ
Express WebTools ('Preferences' tab).
The passwords are stored in the backup file whatever the role used when making the 'Save Set'
operation (as System administrator, Key operator, or Power user). However, the passwords are
restored only when the System administrator or the Power user performs the 'Open Set'
operation.
Password policy
256 characters maximum
Any number [0-9]
Any letter lowercase/uppercase [a-z][A-Z]
the following special characters:
_
- ~ ! @ # $ % ^ * ? { }
( ) = + , . ; : [ ] / | \
Passwords storage on the controller
All passwords are stored encrypted on the controller. There is no open access to the system to
change them.
You can change them only through the standard user interface on the controller.
Password on the printer panel (for Océ PlotWave 750)
You can activate the password to restrict the access to the Administrator settings from the printer
panel. this password is fixed and cannot be changed (refer to the Océ PlotWave 750 Operation
Guide to know more about the password)
Printer panel protection
Introduction
From Océ Express WebTools, you can disable the access to some administration and network
settings from the printer panel.
When the 'System administration from Printer Panel' feature is disabled in the Configuration -
Connectivity settings in Océ Express WebTools, the 'Administrator only' menu is no more
displayed on the printer panel.
Therefore, the following settings are no more accessible from the printer panel:
Network adaptor settings
‘Clear memory’ (job removal)
Activate deactivate buzzer
Activate deactivate password (on the printer panel)
Printer panel protection
Chapter 2 - Security on Océ PlotWave 300/350, PlotWave 750, PlotWave 900 and ColorWave 300