Maintenance
-36-
5
Item Description
Schedule
Note
PSI
Mon
Year
Hydraulic System
Plumbing
Plumbing shall be free of cracks, damage,
twists, or deterioration.
There shall be no leaks in pipes, hoses,
joints, or seals.
Plumbing shall be mounted properly, and
fastening bolts and nuts shall not be loose or
missing.
Breather shall not be clogged.
Hydraulic
Cylinders
Shall work smoothly.
There shall be no leaks when extending and
contracting cylinder.
Extend dump cylinder fully under load
and hold. Stroke shall be within the range
specied by manufacturer.
Cylinder tube and rod shall be free of dents,
cracks, bends, or scratches.
Cylinder mounting pins shall be free of
damage or excessive wear.
Body, Chassis, Loading Deck
Chassis
Frame
Shall be free of cracks, deformation, or
corrosion.
Fastening bolts or nuts shall not be loose or
missing.
Body Panels
Shall be free of cracks or deformation.
Doors shall open, close, and lock properly.
Fastening bolts or nuts shall not be loose or
missing.
Loading Deck
Loading deck shall be raised,lowered and
turned smoothly.
Shall be free of cracks, deformation, or
corrosion.
Fastening bolts or nuts shall not be loose or
missing.
Safety Prop
Safety prop shall be free of any deformation.
Labels
Warning labels and instruction plates shall
be clean, legible, and free of damage.
Safety Devices
Work Lamp
Work lamp shall work.
Lamp lens shall be free of cracks or chipping
and water shall not be in the lamp.
Horn
Horn shall work.

Related product manuals