6.1 HOW TO DETECT AN ERROR
6.2 OPERATING ALARMS
Below are some alarms that may appear on the display.
For all alarms not described in this manual, contact Technical Support.
FILLING UP T.O. (32)
FILLING UP T.O.
CAUSE CONSEQUENCE POSSIBLE SOLUTION
The boiler lling phase
has exceeded the max-
imum time of 9 minutes
as r󰀬 lling, the oth-
ers take 2 minutes; the
probe level (SLC) has
not been reached.
The machine is OFF
and an alarm message
appears on the display.
Check:
If the water supply tap is open.
Cleaning of the water inlet lter.
The water pressure.
The softener sy󰀬em, if any.
To reset the alarm, turn the machine o󰀨 and
then on again.