Manual
23
Error no.
Possible causes Possible error correction
14
Received line number is invalid at RS-232
and Centronics.
Check sent data.
Check connection PC - printer.
15 Invalid length of received mask statement. Check sent data.
Check connection PC – printer.
16 Transferred mask statement invalid. Check set data.
Check connection PC – printer.
17 No end of data found. Check set data.
Check connection PC – printer.
18
One res. several characters of the text is
res. are not available in the selected font.
Change text.
Change font.
19 Unknown transferred data record. Check sent data.
Check connection PC – printer.
20
For check digit control the entered res.
received check digit is wrong.
Calculate check digit anew.
Check code data.
21
Selected SC factor is invalid for EAN res.
UPC.
Check SC factor.
22
Entered digits for EAN res. UPC are invalid
< 12; > 13.
Check number of digits.
23
Selected check digit calculation is not
available in the bar code.
Check calculation of check digit.
Check bar code type.
24 Selected zoom factor is not available. Check zoom factor.
25 Entered sign is not available. Check offset value.
26 Entered offset value is invalid. Check offset value.
27 Printhead temperature is too high.
Defective printhead sensing device.
Decrease the print strength.
Change printhead.
28 While cutting an error occurred – paper jam Check label run.
Check cutter run.
29
Entered data do not correspond to the
characters allowed by the application
identifier.
Check code data.
30
Selected application identifier is not
available in GS1-128 (EAN 128).
Check code data.