Specications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 13/12/2017 237
LED (MS)
OFF No power supply at RV-CAN
Green on is in normal operational state
Green ash
Don't be connected with basic
unit.
Red on
A fatal error has occured.
(Device hardware error).
Red ash
An error has occured.
(communicated with Basic unit
make a retrievable error).
LED (NS)
OFF No power supply at RV-CAN
Green on
RV-CAN is on line and Opera-
ting state
Green ash
and Red
OFF
RV-CAN is Preoperational
state
Green on
and Red
OFF
RV-CAN is on line and Opera-
ting state
Green
single ash
Stop state.. ON2 00ms, OFF
1000ms
Red on
A fatal error has occured.
(RV-CAN has shut down com-
munication).