55
Steps Procedure
Disconnect all wiring, remove screws retaining
control box to compressor partition and lift control
box out of unit.
Remove the screws retaining the reactor to the
compressor partition and remove the reactor.
Reclaim all refrigerant charg in system.
Cut all line connections to 4-way valve and
remove from unit.
12.Remove reactor
13.Remove 4-way valve
11.Remove control box assembly
Control Box Assembly
Reactor
4-Way Valve