62-11863 2-18
2.7 UNIT SPECIFICATIONS
2.7.1 Engine Data
2.7.2 Water Temperature Sensor (WTS)
The WTS is a thermistor type sensor located on the engine cylinder head which measures the temperature of the
coolant.
The unit shuts down if any of the following conditions occur:
Ambient is less than 120°F (5°C) and coolant temperature exceeds 230°F (110°C)
Ambient is greater than 120°F (50°C) and coolant temperature exceeds 240°F (110°C)
Coolant temperature stays between 240°F (110°C) and 230°F (110°C) for five minutes
2.7.3 Lubrication System
Oil pressure switch (OP)
Closes above 15 psig (1.05 bar) ± 3 psig (0.2 bar)
Lube Oil Viscosity: (API classification CD minimum)
Engine Model D1105
Used on Supra 950MT
Displacement 68.5 in
3
(1105 cc)
Do. Cylinders 3
Horsepower 14.9 kw (20 hp) @2400rpm
Weight 214 lbs (97 kg)
Coolant Capacity 5 quarts (4.7 liters)
Oil Capacity without oil bypass kit 10 quarts (9.5 liters)
Operating Speed 2300 - 2350 rpm
Injection Setting 1991 to 2133 psig (140 to 150 kg/cm
2
)
Table 2–7 Lube Oil Viscosity
Outdoor Temperature Recommended Oils
Below 32°F or 0°C 10W30, 5W40 (synthetic)
Above 32°F or 0°C 10W30, 5W40 (synthetic), 15W40
040
32 104
Ambient Temperature
F
O
5W40* (synthetic)
10W30*
15W40**
*10W30 & 5W40 (synthetic) are recommended for ALL climates
**15W40 is NOT recommended for climates < 32 F (0 C)
C
O
F
O
C
O
o
o

Table of Contents