62-11863 3-4
3.5 STARTING UNIT - ELECTRIC / STANDBY OPERATION
WARNING
!
Under no circumstances should ether or any other starting aids be used to start engine.
Make sure the power plug is clean and dry before connecting to any electrical outlet / receptacle.
Do not attempt to connect or remove power plug or perform service and/or maintenance before
ensuring the unit RUN/STOP switch is in the STOP position, the I/O switch is in the OFF (O)
position and the external power circuit breaker is OFF.
1. Place the unit RUN/STOP switch, which is located on the side of the electrical box, in the STOP position.
2. Place the I/O switch in the OFF (O) position.
3. Connect the standby cable to the unit and then turn the external power circuit on.
4. Place the unit RUN/STOP switch in the RUN position.
5. Place the I/O switch in the RUN (I) position.
6. Press the ROAD/STANDBY key until the STANDBY icon is displayed.
7. Press and hold the UNIT DATA/COMP. key to go to compartment selection mode.
8. Select the desired compartment using the UP and DOWN arrow key.
The microprocessor performs a self-test (all display messages appear in display window), after which
time the setpoint and refrigeration compartment temperature is displayed.