Do you have a question about the Carrier Ziton ZP3 and is the answer not in the manual?
| Manufacturer | Carrier |
|---|---|
| Model | Ziton ZP3 |
| Compliance | EN54 |
| Input Voltage | 230V AC |
| Battery Backup | Yes |
| Certifications | EN54 |
| Type | Addressable Fire Alarm Control Panel |
| Network | Yes |
| Compatibility | Ziton devices |
Summarizes declared performance according to Construction Products Regulation.
Describes the reporting system for alarms, faults, and other events on the LCD display.
Explains how the LCD displays alarms by zone, identifying location and event details.
Details navigating multiple alarms using scroll buttons and 'More' indicators.
Details the panel's response to fire alarms, including LED indications and operator actions.
Overview of built-in software functions accessed via the operator menu and keypad.
Explains how to access menus using the panel keypad and describes each button.
Describes alarm view buttons and common alarm indicators on the panel.
Explains how alarms are indicated audibly and visibly on the panel fascia.
Describes control buttons used to navigate the system during an alarm.
Acknowledges an alarm, silences the buzzer, and makes indicators steady.
Clears alarms and restores the panel to a normal state with no alarms.
Silences the building sounders during an alarm condition.
Activates all sounders in the building, for general alert or to restore silenced sounders.
Restores disabled sounders or toggles between Enable/Disable All Sounders.
Explains how alarms are indicated audibly and visibly on the panel fascia.
Details how fire alarms are shown via LEDs, LCD, and status indicators.
Details how fault alarms are shown via LEDs, LCD, and status indicators.
Explains how the LCD displays alarms by zone, identifying location and event details.
Details alarm type, zone screen indication, and total current zone alarms.
Shows event number, zone description, and time of alarm.
Displays alarm type, point screen indication, device address, and type.
Displays the exact location of the device (point) on the panel.
Provides step-by-step actions for responding to a fire alarm.
Categorizes faults into serious and limited faults requiring different actions.
Provides step-by-step actions for responding to a fault alarm.
Categorizes disablements of devices, sounders, and remote manned centre alarms.
Provides step-by-step actions for disabling system elements.
Categorizes other alarms into prealarms, security alarms, non-fire alarms, and service.
Provides step-by-step actions for responding to other types of alarms.
Explains the owner's responsibility for ensuring the fire detection system is maintained.
Details responsibilities for system checks, testing, record keeping, and occupant awareness.