1. General Function
Menu-GEN.01: Set AD Speed
Function
AD Speed Setting
Set Range
(0 ~ 6)
Display Part
Meaning
ADC. 0
Converting speed 5 times per second
ADC. 1
Converting speed 10 times per second
ADC. 2
Converting speed 20 times per second
ADC. 3
Converting speed 40 times per second
ADC. 4
Converting speed 100 times per second
ADC. 5
Converting speed 160 times per second
ADC. 6
Converting speed 320 times per second
Note 1. After changing the AD speed, press Set' key to display the weight using the altered value.
(Press Set' after checking the changed value to return to the previous mode)
Menu-GEN.02: Set average filter
Function
Average filter Setting
Set Range
(1 ~ 50)
Display Part
Meaning
Fil. XX
Initial Value : 10
Setting the number of buffers in the average filter
Note 1. Set based on the environment. (The rate of change of weight may slow)
Menu-GEN.03: Set digital filter
Function
Average filter Setting
Set Range
(0 ~ 5)
Display Part
Meaning
IIR. XX
Initial Value : 0
0 : Filter not use
1 ~ 5 : Filter intensity
Note 1. Set based on the environment. (The rate of change of weight may slow)
Menu-GEN.04: Set use key lock
Function
Set use key lock
Set Range
(0 ~ 1)
Display Part
Meaning
LOCK. 0
Unlock front key
LOCK. 1
Lock front key
Menu-GEN.05: Set Key Operating Conditions
Function
Key Operating Conditions(Zero, Tare) Setting
Set Range
(0, 1)
Display Part
Meaning
K-ST. 0
Always in operation
K-ST. 1
Operates only if the weight is stable