23
22
“ENTER” key usage(CI-2001BS kg version)
0 Not used
1 Total print key
2 HOLD key
3 LCD manual back-light key
F09
Baud rate
0 600 bps
1 1200 bps
2 2400 bps
3 4800 bps
4 9600 bps
5 19200 bps
F11
“ENTER” key usage(CI-2001BS kg/lb version)
0 Not used
1
- Print key(Press “PRINT” key)
- Total Print key(by pressing “PRINT” key more than 3 second.)
2 HOLD key
3 LCD manual back-light key
F09
Device ID
00 00 : Device ID “00”
~
99 99 : Device ID “99”
It is used the no. of indicator when
system is connected.
F10
Output mode
In case selecting No.1
0 of F02, this function No data output
must be set up.
1 Stream mode
2 Transmit only in stable condition
Transmit when data is required
Request signal: device ID
3 (F10 : Device ID)
In case F10 : 1, send hex value
01h in computer
F12
Set HOLD type
0
Average hold: Compute the average weight of
oscillating weights.
1
Peak hold: Compute the maximum weight among
oscillating weights.
2 Sampling hold
F13
Select option clock
0 Not use clock
1 Use clock
F14
Change date/time(Ex. 2000/1/11 13:10:01)
LED Display Meaning
C1 98 Year : 00
C2 12 Month : 01
C3 11 Day : 11
C4 13 Hour : 13
C5 10 Minute : 10
C6 01 Second : 01
: Increase of no.
: Shift of digit
ENTER:
Store and move into
next menu