EasyManuals Logo

CAS CL5000J Series User Manual

CAS CL5000J Series
85 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #47 background imageLoading...
Page #47 background image
47
2.6 Programming Global Setting
2.6.1 Global Label Format (Menu code 1510)
(MENU -> Global Setting -> Label Format)
Label format #51~#60 are free formats that users may modify at their needs. Users may
download one into the scale and set a specific free label format.
You can press the SAVE key at anytime to save the current data and if you want to
exit without saving, press the ESC key.
1. Set Global label No.
Set PLU label number
EX) PLU Label No. = 51
PRINT
1
5
1510
LAbEL
A
PLU
51
2. Set Total label No.
Set PLU label number
EX) PLU Label No. = 29 (default)
PRINT
9
4. Exit menu
If you want to exit, press ESC key.
2
1510
LAbEL
A
totAL
29
X
ESC
3. Set Invert(Reverse) label
Set PLU label number
EX) Non-Invert = 0
Invert = 1
0
1510
LAbEL
A
invErt
0
PRINT

Table of Contents

Other manuals for CAS CL5000J Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CAS CL5000J Series and is the answer not in the manual?

CAS CL5000J Series Specifications

General IconGeneral
BrandCAS
ModelCL5000J Series
CategoryScales
LanguageEnglish

Related product manuals