2.6 Programming Global Setting
2.6.1 Global Label Format (Menu code 1510)
(MENU -> Global Setting -> Label Format)
Label format #51~#60 are free formats that users may modify at their needs. Users may
download one into the scale and set a specific free label format.
You can press the SAVE key at anytime to save the current data and if you want to
exit without saving, press the ESC key.
1. Set Global label No.
Set PLU label number
EX) PLU Label No. = 51
PRINT
1
5
1510
LAbEL
A
PLU
51
2. Set Total label No.
Set PLU label number
EX) PLU Label No. = 29 (default)
PRINT
9
4. Exit menu
If you want to exit, press ESC key.
2
1510
LAbEL
A
totAL
29
X
ESC
3. Set Invert(Reverse) label
Set PLU label number
EX) Non-Invert = 0
Invert = 1
0
1510
LAbEL
A
invErt
0