2.10.4 IP (Menu code 1913)
(MENU -> Communication ->Network Setting->IP)
Setting IP and Port
2.10.5 RS232C Setting (Menu code 1915)
(MENU -> Communication ->Network Setting->B-RATE)
No.
Baud Rate
0
9600
1
19200
2
38400
3
57600
4
115200
1. 2. Set IP address and Port
Scale need to have own TCP/IP
NOTE: Recommend to get this information from authorized network personals
If scale does not connected to internet or any other
POS system, you can set initial IP address (192.168.1.1)
and Gateway (192.168.1.1),
Subnet Mask (255.255.255.0)
If connecting only 2 scale just set different IP address.
Therefore set #1 for 192.168.1.1, and other 192.168.1.2
Set Gateway 192.168.1.1
Leave Port as factory setting.
If IP address changes scale will reboot
1913
iP-SEt
nEt