8
Method 2 P5=3 continuous transmission after stabilization.
Transmitted data is weight. (gross weight, net weight or tare weight, decided by parameter P4).
Gross weight format is : ww000.000kg or ww000.000lb
Net weight format is : wn000.000kg or wn000.000lb
Tare weight format is : wt000.000kg or wt000.000lb
Note : Above decimal point position is determined by decimal point position setting of the indicator.
Method 3 P5=4
Command method (Command character is ASCII code) :
Indicator will do the relevant operation as the command sent by computer
Command R Indicator receives the command and sends the weighing data on time.(format is as same
as continuous method 1)
Command T Indicator receives the command and tare(as same as Tare button), indicator return to
CR LF
Command Indicator receives the command and Zero(as same as Zero button), indicator return to
CR LF
Method 4 P5=5 : continuous transmission
Data format : = <Weight data(including decimal point)>, all data are in ASCII code.
Note: = data format, ASCII code.
<Weight data (including decimal point)> : 6 digits(including decimal point) of weight data with symbol,
ASCII code.
The lower digits are in front, and the higher digits and symbol digits are in the rear. Negative symbol bit is
-, and positive symbol is 0
For example, if the weight showing on the indicator is -500.00kg, the serial output data will be =00.005-
If the weight showing on the indicator is 500.00kg, the serial output data will be =00.005.
Large screen
See scheme 2-4 for wiring details. Scoreboard signal is current loop signal of 20mA constant current and is
output in a serial way through binary code, with a baud rate of 600. Each frame has 11 data bits, including
one start bit(0), eight data bits(LSB in front), one flag bit, and one stop bit(1).