6-MAINTENANCE
4.Cleanaroundthepre-lterbodythenremoveitusing
thewrenchprovidedwiththemachine.
5.Installthenewlterelement.Replacethelterbody
seal,theninstallthebody,turningituntilitisincontact
withthepre-lterhead.
ATTENTION:Donotllthelterbodywithfuelbefore
installing.
6.Tightenthebodyusingthewrench,thetightening
torquemustbefrom28-32N·m(20.7-23.6lbft).
NOTE:Bindtightwithinregulationtorque.
QOIPZB-0065
7.Replacethedrainplug(1)sealtheninstallthedrain
plug(1),thetighteningtorquemustbebetween8N·m
(5.9lbft)12N·m(8.9lbft).
ATTENTION:Overtighteningcandamagetheseal.
ATTENTION:Neverre-usethesealsofthelterbody
orthedrainplug(1);theymustalwaysbereplaced
withnewseals.
NOTE:Bindtightwithinregulationtorque.
8.Bleedthesystem.See"Fuelsystemairbleed".
QOIPZB-005A6
Bleedthelter
Proceedinthesamemannerasforthepre-lter.See
"Pre-lterbleeding".
CGVFRL-002A7
Replacingthelterelement
ATTENTION:IfafuellterotherthanagenuineCASE
CONSTRUCTIONlterisused,theguaranteewillnotbe
appliedtoafaultcausedbytheuseofawronglter.
6-29

Table of Contents

Related product manuals