6-MAINTENANCE
8.Switchthevalvesothatthefuellinecanbeusedfor
operation.
IMO116-009A11
Cleaningthefuelsupplypumplter
1.Locatednearthefuelpre-lter,placeareceptacleof
suitablecapacityunderthesupplypump.
9W2YCK-00212
2.Openthepumpbodyandextractthelter(2)andthe
seals(1)and(3).
WARNING
Flyingdebris!
Compressedaircanpropeldirt,rust,etc.into
theair.Weareyeandfaceprotectionwhen
usingcompressedair.
Failuretocomplycouldresultindeathorse-
riousinjury.
W0307A
3.Cleanthelterwithcompressedair.Checkthelter
andreplaceitifnecessary.Replacethesealswithnew
seals.
4.Carefullycleanthebody(4)andthecover(5).Nodirt
mustremaininthesupplypump.
5.Re-assemble,takingcaretoinstallthesealsinthe
correctorderthenre-installthepump.
6.Openthevalveonthesupplyline.
7.Bleedthesystem.See"Fuelsystemairbleed".
EQFU5N-00513
6-31