CEBORA S.p.A. 29
3.302.002 03/08/00
5.5 - Control board (62) code 5.602.027/A.
5.5.1 - Topographical drawing.
5.5.2 - Connector table.
Conn. Terminals Function
J1 1 – 4 “transfer arc” output.
J1 3 – 4 current digital reference input.
J2 1 – 2 current set-point PWM output.
J2 1 – 3 IGBT driver command output.
J2 5 – 6 block input from driver board (9).
J3 1-2-3-4 torch recognition output.
J4 1 – 2 power source start command input.
J5 2 - 4 “cooling unit presence” input.
J5 3 - 4 “cooling liquid pressure” input.
J6 1 - 2 “power source temperature” input.
J6 3 – 4 “pressure 1 gas” input.
J6 5 – 6 “pressure 2 gas” input.
J7 1 – 2 “electrode finished” digital reference output.
J8 1 – 2 transfer reed input.
J9 1 – 2 “capacitor (40) pre-charge complete” input.
J10 1 – 2 “hazardous voltage” input
J10 5 – 6 PWM "electrode finished” input.
J11 1 – 34 operator panel inputs/outputs.
J12 1 – 2 solenoid valve EL4 output (n.u.).
J12 3 – 4 solenoid valve EL3 output.
J12 5 – 6 solenoid valve EL2 output.
J12 7 – 8 solenoid valve EL1 output.
J12 9 – 10 remote switch output (18).
J12 11–12 internal HF cut-out output.
J13 1 – 2 remote switch output (5).
J13 3 – 4 socket command output (21).
J13 5 – 6 pre-magnetization output (79).
J13 7 – 8 capacitor pre-charge output (40).
J14 1 – 2 power supply input board (62).
J14 3 – 4 AC service power supply input.
J15 1 – 2 input “autopilot”.