CEBORA S.p.A. 12
3.302.002 03/08/00
Correct?
Correct?
Correct?
3.3.2 - Power source powered, operator panel (64) on, fan (77) stopped.
CAPACITOR PRE-CHARGING (40) AND TRANSFORMER PRE-MAGNETIZATION (79)
TEST.
q Capacitor (40), terminals + and – = > 200 VDC, and remote switch (5) closed, after closing
the switch (60).
YES
NO
See “Pre-charge board power supply test” par. 3.3.2.
Check the wiring between J3 board (7) and J13 board (62).
Check the wiring between J2 board (7) and J9 board (62).
Check the wiring between the remote switch (5) coil terminals and J13 on board
(62).
Replace board (7).
Replace board (62).
Replace remote switch (5).
VENTILATION TEST.
q Fan (77), terminals A (black wire) – H (blue wire), on the faston patch connector = 230
VAC, after closing the remote switch (5).
NO
YES
Check the wiring between the fan motor (77) and starting capacitor connected to
terminals A and K of the motor (77).
Replace starting capacitor.
Replace motor (77).
Check the wiring between power voltage change and motor (77).
Make sure the voltage change is correctly positioned.
Check for the presence of the three power supply phases on the primary circuit of the
transformer (79).
PRE-CHARGE BOARD POWER SUPPLY TEST.
q Pre-charge board (7), connector J1 terminals 1 - 4 = 180 VAC.
YES
NO
Check the wiring between connectors J1 on board (7) and J1 on board (8).
Check fuse F1 on board (8); if broken, replace and make sure that terminals 1 - 4
of J1 on board (7) are not short-circuited. If so, replace board (7).
Check the 180 VAC on terminals 0 – 180 of board (8); if missing, check the
wiring between the service transformer and board (8), or replace the service
transformer (8). If present replace the fuse board (8).
Regular power supply to pre-charge board (7).