Page 26 •
CEDIMA
®
• Technical Documentation • All rights reserved as per DIN 34 • „Subject to modifications due to progressive development“ •
Sect. 6 - Troubleshooting
Bench Saw CTS•81, L, XL
Operating Manual 70 9998 0329 / UK 003
6. Troubleshooting
6.1 General problems affecting the Bench Saw
Problem Possible cause Remedy
Bench Saw won’t start after pu-
shing the ON button
Mains cable not properly con-
nected
Check connection to mains.
Mains cable defective Have mains cable replaced by
qualified electrician.
Mains switch defective Have mains switch replaced by
qualified electrician.
Internal wiring of Bench Saw
defective
Have internal wiring inspected
and repaired by qualified electri-
cian.
Blade drive motor defective Have motor replaced by quali-
fied electrician.
Blade drive motor will switch
off automatically
Cutting pressure too high Reduce cutting pressure.
Wrong saw blade type Install correct saw blade type.
Defect in electrical installation Have Bench Saw inspected and
repaired by qualified electrician.
Blade drive motor will provide
insufficient power
Power loss resulting from exces-
sive length of mains cable
Use shorter mains cable.
Power loss resulting from
wound-up cable drum
Unwind cable from drum.
Blade drive motor defective Have motor replaced by quali-
fied electrician.
Insufficient or missing cooling
water supply
Wet-pit pump is running dry Verify that wet-pit pump is fully
submerged in the water.
Fill in more water.
Filtering screen of wet-pit pump
is clogged
Clean filtering screen.
Pump impeller of wet-pit pump
is dirty
Open wet-pit pump and clean
impeller (see sect. 5.4).
Wet-pit pump defective Have wet-pit pump replaced by
qualified electrician.