Use and maintenance manual
In the standard machine setting as VIRTUAL SONAR (AWA and AUTOADAPTIVE enabled), at the end of the automatic
distance and diameter measurement, perform a measuring spin.
In the case of particular rims, the wheel balancer may ask you to set the tyre width value in mm.
Set the width value shown on the tyre and proceed with balancing the wheel.
If the wheel dimensions have been entered incorrectly, the parameters can be modified without repeating the
balancing spin:
1. Press:
2. Set the value of the dimensions in sequence:
b=width
d=diameter
a=distance
using the buttons
.
3. Press the button to confirm the setting and go to the next dimension.
Press the button at any time to interrupt dimension setting and return to the main screen.