6.3 BALANCING WITH A MIX OF ADHESIVE AND CLIP-ON WEIGHTS AND STATIC BALANCING
After dimension acquisition in standard balancing mode, pressing the buttons
3
2
1
4
5
, you
can select one of the following correction modes.
WEIGHT APPLICATION POSITION
Correction type Inside Outside
Clip-on weight at 12 o’clock Clip-on weight at 12 o’clock
Clip-on weight at 12 o’clock Adhesive weight at 12 o’clock
Adhesive weight at 12 o’clock Clip-on weight at 12 o’clock
Adhesive weight at 12 o’clock Adhesive weight at 12 o’clock
STATIC
Adhesive weight at 12 o’clock
After dimension acquisition in ALU mode, pressing the buttons
3
2
1
, you can select one of the fol-
lowing correction modes. The adhesive weight application distance and diameter are measured by means of the
automatic gauge, except for the static unbalance where the dimensions acquired are modified following some
fixed parameters.
WEIGHT APPLICATION POSITION
Correction type Inside Outside
Adhesive weight at 12 o’clock Adhesive weight at 12 o’clock
Clip-on weight at 12 o’clock Adhesive weight at 12 o’clock
STATIC
Adhesive weight at 12 o’clock