6
16
Sets the conditions under which the Alarm channel (Output 3)
will activate. Also sets the anti-default and tone mute features.
The following alarm conditions can be set:
Duress (Code + 1)(Default = off):
Adding 1 to the last digit of an access code activates the unit as
normal, but also activates the alarm channel. This is used if
entering under duress. E.g. Access code is 1234: Entering
1235 gives access, but also activates the alarm channel.
Alarm ( + #)(Default = off):
Pressing the and # keys simultaneously activates the
alarm channel.
Wrong codes (Default = off):
When the number of wrong codes is exceeded, the alarm
channel is activated.
Anti Default feature (Default = off):
Setting this feature prevents the master code and system
parameters from being reset by the defaulting features.
Tone Mute feature (Default = off):
Setting this feature turns off the audible feedback when
Setting the security parameters