control sends by default). When 'None' is selected,
the C1 cannot be controlled by a remote control
anymore.
CALIBRATE Start calibration C1 should be warmed-up Launch automated calibration left and right channel
DAC stage. It takes about 40s per channel to
complete. For optimal performances, please make
sure the C1 is warmed-up (i.e. turned on for more
than an hour) before running calibration.
NETWORK Reset None Clears the C1's memory of other CH Precision
devices it has discovered through the TCP/UDP
proprietary protocol.
Details of FACTORY SETTING menu Parameters
4.3.1.5 INSTALLED OPTIONS
The C1 SETUP >> OPTIONS menu provides read-only information about installed
slot-in boards. Details are:
- SYNCHRO:
- ETHERNET:
- SLOT 1:
- SLOT 2:
- SLOT 3:
Synchronization option installed
Board type in the Ethernet slot: CONTOL (default) or
NETWORK (streaming option)
Input board installed in Slot 1
Input board installed in Slot 2
Input board installed in Slot 3
Each slot indicates the type of board it handles. A '-' indicates that the slot is
currently unpopulated.
The following table details the Parameters of the INSTALLED OPTIONS menu:
PARAMETER PARAMETER VALUES REQUIRED OPTIONS REMARKS
SYNCHRO Clock In/Out
-
SYNC_IO board Reports the presence of the SYNC_IO board in the
corresponding slot. If SYNC_IO is not installed, the
Parameter reads '-'.
ETHERNET Control
Network
CONTROL board
NETWORK board
Reflect which board type populates the Ethernet
slot. This slot has to be populated, by one of these
two boards.
SLOT 1
SLOT 2
SLOT 3
Digital In 1/2/3
USB In 1/2
Analog In 1/2
Phono MC 1/2
-
At least 1x DIGITAL_IN Parameters report which type of board
(DIGITAL_IN, USB_IN, ANALOG_IN or none) are
installed in the different slots.
'-' indicates that no board is installed in the given
slot.
Parameters are Read Only
Details of INSTALLED OPTIONS menu Parameters
42 C1 User Manual Rev 1.9