D1 - C1 connection when SYNC_IO equipped
When paired with a hybrid configured D1 (DIGITAL_OUT L/R + ANALOG_OUT Ls/RS and C/Sub), recommended setup is still the
same (i.e. clock goes from C1 to D1 to have optimal conversion condition for main channels). In such case:
• D1 clock source: SYNCHRO BNC 75 Ohm
• C1 clock source (for this input): INTERNAL
4.5.4 3x C1 D/A controllers + multichannel D1 drive (all with SYNC_IO board)
In this 4-unit multichannel setup (D1 with all 6 channels digital out + 3 C1 DAC pairs), when all units are equipped with SYNC_IO
boards, we still recommend that the C1 processing the main channels is the clock master. The D1 is slaved to this C1's clock, and
generates a synchronization signal for the two other C1s (Ls/Rs and C/Sub ones). Schematic below shows optimal way to connect
such system: