4.3.1.6 NETWORK
The C1 SETUP >> NETWORK menu allows knowledge and customization of the
network related Parameters of the unit. Accessible Parameters are:
- STATUS:
- CONFIGURE:
- ANNOUNCE:
Listing of all CH products detected (product type, IP and
MAC addresses
Defines if the C1 should interact with the network as the
master, slave or not (offline)
Forces the C1 to send a broadcast message on the local
network to announce itself
The following table details the Parameters of the NETWORK menu:
PARAMETER PARAMETER VALUES REQUIRED OPTIONS REMARKS
STATUS IP address
Product type
MAC address
Connection to a router
via its RJ-45 Ethernet
port (on the Control
board).
When the C1 is in standby, it searches its attached
network (front LED blinking) for other CH products.
All detected CH products are listed here, starting
with current C1.
Parameters are Read Only
CONFIGURE This C1 is master
This C1 is slave
This C1 is offline
Connection to a router
via its RJ-45 Ethernet
port (on the Control
board).
When physically connected to a network, the C1 can
ignore this network (offline) or connect to it as
being the master (it will transmit IR received
commands to all slave) or as a slave (it will ignore
remote control commands and receive commands
from the master device).
There must be no more and no less than one master
in a CH network.
This networking facility enables information sharing
among CH products (such as sound level for
multichannel D1+C1 configurations).
ANNOUNCE Broadcast Connection to a router
via its RJ-45 Ethernet
port (on the Control
board).
Forces the C1 to send a broadcast message on the
local network to announce itself. This forces other
devices to detect it, and send back acknowledge
messages with their own information.
Details of NETWORK menu Parameters