84
Regulation
ARIANEXT COMPACT
MENU
SUB-MENU
PARAMETER
DESCRIPTION
RANGE DEFAUTL
17 2 2 Load shedding enable
Not defi ned
Not present
Present
Not defi ned
17 2 3 AFR contact confi guration
None
Auxiliary CH pump
Alarm
None
17 2 4 Pro-Tech anode active OFF - ON OFF
17 2 5 kWh Primary Energy/kWh Elec Energy Factor
17 3 Central Heating
17 3 0 CH pump prerun time 30
17 3 1 Time for prerun new attempt 90
17 3 2 CH pump overrun 3
17 3 3 Pump Speed Control
Low speed
High speed
Modulating
Modulating
17 3 4 Delta T Pump Setpoint 5
17 3 7 Max PWM Pump 100
17 3 8 Min PWM Pump 100
17 3 9 Floor drying Flow Set Point Temperature 55
17 4 Domestic Hot Water
17 4 0 DHW Comfort Setpoint Temperature 55
17 4 1 DHW Reduced Set Point Temperature 35
17 4 2 Night tariff contact
Not defi ned
Not present
Present
Not defi ned
17 4 3 Comfort function
Disabled
Time Based
Always Active
HC-HP
HC-HP 40°C
Green
Always Active
17 4 4 Max HP charging time 120 (min)
17 4 5 Antilegionella Function OFF - ON OFF
17 4 6 Antilegionella frequency 528 (h)
17 4 7 Antilegionella target temperature 60
17 4 8 Max Duration Antilegionella 6 (h)
17 4 9 Antilegionella start time
17 5 Manual Mode - 1
17 5 0 HP circulator control OFF - ON OFF
17 5 1 Manual mode activation
OFF
Low Speed
High Speed
OFF
17 5 2 Diverter valve control
DHW
CH
CH
17 5 3 Diverter valve COOLING
CH
COOLING
CH
17 5 4 Auxiliary circulator OFF - ON OFF
17 5 5 AFR contact OFF - ON OFF
17 5 6 Test resistance 1 OFF - ON OFF