EasyManua.ls Logo

CHAFFOTEAUX ARIANEXT COMPACT User Manual

CHAFFOTEAUX ARIANEXT COMPACT
92 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
FR
ARIANEXT COMPACT
Notice technique d’installation et d’entretien
Cette notice est destinée aux appareils installés en France
IT
Istruzioni tecniche per l’installazione e la manutenzione
Installation and Servicing Instructions
GB
OK

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the CHAFFOTEAUX ARIANEXT COMPACT and is the answer not in the manual?

CHAFFOTEAUX ARIANEXT COMPACT Specifications

General IconGeneral
BrandCHAFFOTEAUX
ModelARIANEXT COMPACT
CategoryHeat Pump
LanguageEnglish

Summary

SAFETY REGULATIONS

Key to symbols

Symbols used in safety regulations.

WARRANTY

Abnormal conditions of the installation

Conditions that void the appliance warranty.

Marcatura CE

Compliance with CE directives.

Characteristics of the water supplied to the appliance

Water quality requirements for optimal appliance performance.

System compositions

Components included in the ARIANEXT COMPACT system.

Data plates

Internal unit data plate

Details on the data plate of the internal unit.

External unit data plate

Details on the data plate of the external unit.

Installation of the external unit

Choice of placement

Guidelines for selecting the optimal location for the external unit.

Weights and dimensions

Physical specifications and measurements of the external unit.

Minimum distances to installation

Required clearances around the external unit for installation.

Condensation drain pipe and pre-cut holes on the base of the outdoor unit

Connecting the condensate drain and using pre-cut holes.

Installation of the internal unit

Weights and dimensions

Physical specifications and measurements of the internal unit.

ARIANEXT FSP 1 ZONE

Hydraulic connections for the 1 Zone FSP internal unit.

ARIANEXT FSP 2 ZONES

Hydraulic connections for the 2 Zones FSP internal unit.

Hydraulic connections

Internal unit 1 Zone

Connecting the 1 Zone internal unit to the system.

Internal unit 2 Zones

Connecting the 2 Zones internal unit to the system.

Available pressure

Information on managing available pressure in the system.

Cleaning the heating system

Procedures for cleaning the heating system.

Electrical connection

Electrical circuit

Overview of the electrical circuit and connection requirements.

External unit electrical connection

Connecting the external unit electrically.

Electrical connections of the internal unit

Connecting the internal unit electrically.

Electrical scheme

Diagram illustrating the electrical connections.

Installation of system interface

Positioning

Guidelines for positioning the system interface.

Wall installation

Steps for mounting the system interface on the wall.

Connection to the installation

Connecting the system interface to the internal unit.

Commissioning

Buttons and Display

Description of buttons and display elements on the control unit.

LED indications

Meaning of different LED indicators on the control unit.

Ignition procedure

Steps to initiate and configure the system interface.

PACMAN Param

Parameters related to PACMAN configuration.

Energy manager parameter 1

Configuration of the first energy manager parameters.

Energy manager parameter 2

Configuration of the second energy manager parameters.

Central Heating

Settings for central heating operation.

Domestic Hot Water

Settings for domestic hot water functions.

Error History

Reviewing past system errors.

Reset Menu

Options for resetting system settings.

Thermoregulation

Zone 1 Parameters

Parameters for Zone 1 temperature control.

Zone 1 settings

Specific settings for Zone 1.

Zone 1 Diagnostics

Diagnostic information for Zone 1.

Z1 Zone Module Settings

Configuration of Zone 1 module settings.

Zone2 Parameters

Parameters for Zone 2 temperature control.

Z2 Settings

Specific settings for Zone 2.

Z2 Zone Module Settings

Configuration of Zone 2 module settings.

Regulation

PACMAN Param

Parameters related to PACMAN configuration.

User Parameters

General user-configurable system parameters.

Energy manager parameter 1

Configuration of the first energy manager parameters.

Energy manager parameter 2

Configuration of the second energy manager parameters.

Central Heating

Settings for central heating operation.

Domestic Hot Water

Settings for domestic hot water functions.

Manual Mode - 1

Manual activation of system components (part 1).

Manual Mode - 2

Manual activation of system components (part 2).

Test & Utilities

Accessing test functions and utilities.

HP Diagnostics - 1

Diagnostic information for the heat pump (part 1).

HP Diagnostics - 2

Diagnostic information for the heat pump (part 2).

Energy Manager Diagnostics

Diagnostic information for the energy manager.

External unit thermodynamic performances

Application 30/35

Performance data for Application 30/35.

Application 40/45

Performance data for Application 40/45.

External unit technical data

Technical specifications of the external unit.

Working limits

Operating range for the external unit.

Performances domestic hot water (DHW)

Domestic hot water performance data.

Technical data

System interface

Technical specifications of the system interface.

Outdoor sensor

Installation guidelines for the outdoor sensor.

Maintenance

General remarks

General checks to perform during maintenance.

Functional test

Steps for performing a functional test after maintenance.

Heating circuit draining and use of anti-freeze products

Procedures for draining the heating circuit and using antifreeze.

Information for the user

Guidance for informing the user about appliance operation and maintenance.