Model HP 115V 230V 1ph 230V 3ph 460V 575V
LGJ (OBSOLETE) 1/2 5
ATS2113X 1/4 5
ATSW * 6A
MGJ ** 1/2 6 2.1 1.1
MT, MJ & MH ** 1/2 6
APT 1/2 11.2
T, J & H 1/3 8.5 4.2 3
T, J, H, HJ, DJ, DHJ, & SD *** 1/2 11.2 5.6 3.1 1.75 1.4
T, J, H, HJ, DJ, DHJ, & SD 3/4 13.6 6.8 4 2 1.6
T, J, H & SD 1 16 8 6 3 1.8
GT*** 1/2 11.2 5.6 3.1 1.75 1.4
GT 3/4 13.6 6.8 4 2 1.6
GT 1 16 8 6 3 1.8
GT 1-1/2 20 10 7 3.5 2.75
GH & GSD*** 1/2 11.2 5.6 3.1 1.75 1.4
GH & GSD 3/4 13.6 6.8 4 2 1.6
GH & GSD 1 16 8 6 3 1.8
GH & GSD 1-1/2 20 10 7 3.5 2.75
GH 2 843
GH 3 10.6 4.8
TABLE 1 Amperage By Model/Horsepower And Voltage (All Voltages Are 60Hz)
TABLE 2A
SINGLE-PHASE OPERATORS/Wire Needed For Distance Between Operator And Electrical Box
TABLE 2B
THREE-PHASE OPERATORS/Wire Needed For Distance Between Operator And Electrical Box
Amps 50 FT 100 FT 200 FT 350 FT 500 FT 750 FT
1000 FT
12 1286420
11 121064210
10 121064210
9 121064220
8 141086421
7 141286422
6 141286422
5 1612108642
4 1614108644
3 18141210 8 6 4
2 2016141210 8 6
1 22201614121010
Amps 50 FT 100 FT 200 FT 350 FT 500 FT 750 FT
1000 FT
12 8621
11 106410
10 106420
9 106420
8 108421
7 1286220
6 1286420
5 121064210
4 141086421
3 141286422
2 1614108644
1 2016141210 8 6
E
General Information
Amperage
NOTES:
*Rated Load: 600 in-lb/sec (50 ft-lb/sec)
**Rated Load: 125 ft-lbs/sec