Champion Compressors Pty. Ltd. Manual No. 975425 Rev. C
60
8.5.5 Purge Line Filter Maintenance
The purge line filter should be cleaned after the first 250 hours of service,
checked every 1500 hours of service for blockages or other problems, and be
replaced when the separator element is replaced.
When replacing the separator element, adjust the purge line tube so that it
sits centrally with a maximum clearance of 3mm (minimum clearance is 0mm)
from the separator element base when the separator element is installed
(refer Figure 14 - Purge Line Filter).
Ensure that the purge line filter is fitted in the correct direction of flow
(indicated by the arrow on the side of the filter).
Figure 14 - Purge Line Filter