CHCNAV RS10 USER MANUAL | 2024-04 P a g e | 17
4.3 One-Key control
The RS10 is embedded with one-key acquisition software, equipped with one button
(including a LED indicator), the RS10 can be controlled by a single key to complete data
collection.
Note: In One-Key control mode, you cannot select the capture scene, which defaults to
indoor scene. CORS account login is not available.
▪ RS10 Power On: Long press the device’s “ON/OFF key” for 5s, the indicator light is green,
which means the lidar is powered on successfully.
▪ Device diagnostics: 5s after powering on, the device enters diagnostic mode, with the
green light flashing rapidly at 2Hz. If no issue is detected in device diagnostics, the green
light will be steady on.
▪ Start project: Short press the device’s “ON/OFF key” to start project, the green light
remain steady on.
▪ Device initialization: Initialization starts automatically , laser rotation indicates that the
device is initializing. please keep the device stable and ensure no obstructions around.
▪ Start data acquisition: After the initialization is successful, the device will start data
collection automatically. At this moment, the green light is flashing slowly at 0.5Hz.
▪ Stop data acquisition: Short press the device’s “ON/OFF key” to stop data acquisition.
▪ RS10 Power Off : Long press ON/OFF Key or 5s to turn off.
4.4 Hot-swapping battery
The RS10 battery compartment can only accommodate one battery at a time, but it is
equipped with super capacitors internally, enabling support for hot-swappable battery
replacement. During the data collection , when hot-swapping batteries, it is essential to note
that after removing the battery, a 60-second battery replacement reminder interface will
appear on the tablet.
Note: It is necessary to complete the battery replacement within 60 seconds while ensuring
that the device's position and orientation remain consistent before and after the battery
replacement.