UTM-1 Getting Started Guide | 37
Chapter 4
Restoring Factory Defaults
In This Chapter
Restoring Using the WebUI 37
Restoring Using the Console Boot Menu 38
Restoring Using the LCD Panel 39
As part of the troubleshooting process, it may be necessary to restore the UTM-1 appliance to
its factory default settings.
A UTM-1 appliance can be restored to the factory default image:
Using the WebUI
Through the console boot menu
Using the LCD panel (not applicable to UTM-1 130)
Important - Restoring factory defaults deletes
all information on the appliance.
Restoring Using the WebUI
Use the WebUI of the applicable operating system to restore the appliance to the factory
default settings. You can select one of the software images that are available on the appliance.
Gaia
Use the Gaia WebUI to restore the default factory settings.
To restore a Gaia appliance with the WebUI:
1. Open an Internet browser to the management IP address,
https://<appliance_ip_address>
2. Log in to the WebUI of the appliance using the administrator username and password.
3. In the WebUI, click Maintenance > Factory Defaults