3. Scan Tool, Operating Method and Function Introduction
3.1 Operating Method
* Ignition off, connect scan tool to diagnostic connector, then turn ignition on.
* Enter 03, then press Q keyABS will be in operation condition.
* Enter the function code.
* Enter 06, then press Q keyexiting
* After power off, remove scan tool.
3.2 Function Introduction
* Function 01condition information display
* Function 02fault inquiry
* Function 03hydraulic controlled unit diagnostic
* Function 04filling fluid and bleeding
* Function 05clearing fault codes memory
* Function 06endexit.
* Function 07controller programme
* Function 08measured data display (such as wheel speed signal etc.)
3.3 Key
* Key C Cancel, change input data and current menu
* Key Q Confirm entering
* Key Next
* Key HELP Help Information