4 Long Brake Pedal Travel Possible Causes
[Note]Visually inspect if there is an external leakage or mechanical
problem. Check if there is air in system by bleeding method. Check if
normally closed valve exist a leakage problem using haydraulic unit function
on scan tool.
●brake fluid leakage
●normally closed valve leakage
●there is air in system
●brake rotor heavily worn
●manual brake misadjusted
Visually inspect if fitting leaking.
N
OT NORMAL
Tignten fitting to specified torque.
N
ORMAL
N
OT NORMAL
Replace brake rotor.
Check if brake rotor worn?
N
ORMAL
N
OT NORMAL
Replace manual brake adjuster unit.
Check manual brake adjuster unit.
N
ORMAL
Bleeding check
N
ORMAL
N
OT NORMAL
Re
p
eat bleedin
g
p
rocedures
Check if there is a normally closed valve
leakage using HCU DIAGNOSTIC
FUNCTION on scan tool.
N
OT NORMAL
Replace HCU
(Hydraulic Controlled Unit)