EasyManua.ls Logo

Chery A11 2003 - Page 712

Chery A11 2003
784 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4 Long Brake Pedal Travel Possible Causes
NoteVisually inspect if there is an external leakage or mechanical
problem. Check if there is air in system by bleeding method. Check if
normally closed valve exist a leakage problem using haydraulic unit function
on scan tool.
brake fluid leakage
normally closed valve leakage
there is air in system
brake rotor heavily worn
manual brake misadjusted
Visually inspect if fitting leaking.
N
OT NORMAL
Tignten fitting to specified torque.
N
ORMAL
N
OT NORMAL
Replace brake rotor.
Check if brake rotor worn?
N
ORMAL
N
OT NORMAL
Replace manual brake adjuster unit.
Check manual brake adjuster unit.
N
ORMAL
Bleeding check
N
ORMAL
N
OT NORMAL
Re
p
eat bleedin
g
p
rocedures
Check if there is a normally closed valve
leakage using HCU DIAGNOSTIC
FUNCTION on scan tool.
N
OT NORMAL
Replace HCU
(Hydraulic Controlled Unit)
21
Chery SQR7160 series sedan ABS systemfault diagnostic and repairing

Table of Contents

Related product manuals