EasyManua.ls Logo

Chigo CCB-18HVR4 - Outdoor Unit Service Space Requirements

Chigo CCB-18HVR4
159 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
R3250Hz Universal Series Technical Manual
109
GD Chigo Heating & Ventilation Equipment Co., Ltd.
Model
COU-48HZDR4
COU-55HZDR4
Outdoor power supply
V/Ph/Hz
380~415/3/50
380~415/3/50
Cooling
Capacity
KW
7.0-14.0-15.5
7.5-16.0-17.0
Power input
W
1000-4850-5700 1300-5800-6200
Current input
A
2.5-13.7-14.3
3.4-14.8-15.6
Heating
Capacity
KW
8.0-15.2-16.0
8.5-16.8-17.5
Power input
W
1100-4820-5900 1400-5360-6400
Current input
A
2.8-13.9-14.8
3.6-15.0-16
Compressor
Model
MVB40F
KTQ42D1UMU
Type
DC/Twin-rotory DC/Twin-rotory
Brand
Mitsubishi
GMCC
Frequency range
Hz
12-120
12-120
Capacity
W
13250
13700
Input
W
4150
3700
Current(RLA)
A
14.6
7.02
Refrigerant oil
ml
1250
1400
Outdoor fan motor
Model
DR-380-100-8 DR-380-100-8
Power output
W
77
77
Speed
r/min
780/630
780/630
Insulation class
B B
Outdoor coil
Number of rows
2
2
Tube pitch(a) x row pitch(b)
mm
25×21.65
25×21.65
Fin spacing
mm
1.6
1.6
Fin type
Hydrophilic
Hydrophilic
Tube outside dia. and type mm
9.52
9.52
inner grooved
inner grooved
Coil length x height x width
mm
995×1350×43.3 995×1350×43.3
Number of circuits
7
7
Outdoor air flow(High speed)
m3/h
6100
6100
Outdoor noise level
power level
dB(A)
70 70
pressure level
58
58
Outdoor unit
Dimension(W*H*D)
mm
1014×1430×450
1014×1430×450
Packing(W*H*D)
mm
1095×1545×485
1095×1545×485
Net/Gross weight
kg
109/123.6 112/126.6
Refrigerant type/quantity
g
R32/3800
R32/3800
Throttle part
EXV
EXV
Design pressure
MPa
4.5/1.6 4.5/1.6
Max pressure
MPa
4.5
4.5
Connection wire
Power wiring
mm2
5×2.5
5×2.5
Signal wiring
mm2
4×2.5 4×2.5
Refrigerant piping
Liquid side/Gas side
mm
Φ9.52/Φ15.88
Φ9.52/Φ15.88
Max. pipe length
m
65
65
Max. high drop
m
30
30
Ambient temp
cooling
°C
-15
50
-15
50
heating
°C
-15
30
-15
30

Table of Contents