13.0. ALARMS:
13.1. The following errors will stop the operation of the coolant system and
cause the ES relay to change states:
13.1.1. Main motor starter overload trip.
13.1.2. Return pump overload trip.
13.1.3. Dirty filter, pressure switch 1PS.
13.2. To reset a fault:
13.2.1. Determine the cause of the fault and correct. Reset motor overload(s), and/or
correct dirty filter (switch selector valve to clean filter or replace dirty filter
cartridge). Note: power to unit must be cycled off/on to reset the ES relay
circuit. Re-energize the required “M” code to start the ChipBLASTER.
14.0. PREVENTATIVE MAINTENANCE:
DO NOT ATTEMPT ANY SERVICE ON ChipBLASTER UNIT
WITH POWER ENERGIZED. REMOVE ALL ENERGY
SOURCES AND LOCK OUT / TAG OUT.
!