EasyManua.ls Logo

ChipBLASTER STANDARD UNIT D30-80-1 - Page 56

ChipBLASTER STANDARD UNIT D30-80-1
80 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ChipBLASTER Inc
56
20.0. ELECTRICAL DRAWINGS (Cont.):
Kiwa Interface
D16 & D30 TO KIWA
POWER CABLE
JRG
JRG
04JUN07
7420
12
AS NOTED
A
1:2
WIRE MARKERS, TYTON TAG 26L-105
INSERT 12 PIN FEMALE, HARTING 09 38 012 2701
MARK BOTH ENDS OF WIRES WITH WIRE MARKERS - ITEM 11
SHIELDED CABLE, #20-4 (WEST PENN #3011)
INSERT 12 PIN MALE, HARTING 09 38 012 2601
# 10 AWG THHN BLACK WIRE, 90° C
# 10 AWG THHN GREEN WITH YELLOW STRIPE WIRE, 90° C
NON-METALIC FITTING, 3/4" STRAIGHT, T&B LT502
NON-METALIC FLEXIBLE CONDUIT, 3/4", GRAY, CARLON
CONDUIT ADAPTER, HARTING 73 00 000 5314
DESCRIPTION AND MFG. PART NUMBER
SIDE ENTRY HOOD, HARTING 09 30 024 0540
15 FT
3
5
LEAVE SLACK (2" MIN) SO THAT CONNECTOR
CAN BE OPENED IN ORDER THAT
ADDITIONAL CONDUCTORS MAY BE ADDED
IF REQUIRED.
7
3
1
4
7
6
5
2
8
11
10
9
12
L33
PIN CRT. #
1
2
L1
L2
6
12
5
4
7
8
10
9
6
11
GND
10
17FT
15 FT.
17 FT.
QT'Y.
51 FT.
11
10
9
8
7
5
4
6
1
1
2
2
2
3
ITEM
1
2
CB PART No.
1,2,4,10,11
----
5129
5809
5810
5484
5590
5807
5506
5095
5099
3
5
6
3L3
PIN CRT. #
9
2
1
L2
L1
10
12
11
4
5
8
7
9
6
GND
10
11
9
12
6
7
5
8
3
1
4
2
20.0

Table of Contents