EasyManua.ls Logo

Chroma 6430 - Page 54

Chroma 6430
67 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Programmable AC Source 6430/6420/6415 User‘s Manual
FREQuency
Description: This command sets the output frequency.
Syntax: [SOURce:]FREQuency[:CW|:FIXed] <NRf+>
Parameters: 45 to 500
*RST Value: 60 Hz
Example: FREQ 120 It sets the output frequency to 120Hz.
FREQ MAX It sets the output frequency to 500Hz.
Query Syntax: [SOURce:]FREQuency[:CW|:FIXed]?
Return Parameters: <NR2>
Query Example: FREQ? It returns the set value of output frequency.
VOLTage
Description:This command sets the AC rms output voltage amplitude. The maximum value
is dependent on voltage range and the setting of voltage limit.
Syntax: [SOURce:]VOLTage[:LEVel][:IMMediate][:AMPLitude] <NRf+>
Parameters: 0 to 300
*RST Value: 0
Example: VOLT 110 It sets the AC rms output voltage to 110V.
Query Syntax: [SOURce:]VOLTage[:LEVel][:IMMediate][:AMPLitude]?
Return Parameters: <NR2>
Query Example: VOLT? It returns the set value of output voltage.
VOLTage:EPRogram
Description: This command enables or disables the external program mode. During external
program mode, the AC rms output voltage is controlled by an external reference
DC voltage.
Syntax: [SOURce:]VOLTage:EPRogram[:STATe] <Boolean>
Parameters: OFF | ON
*RST Value: OFF
Example: VOLT:EPR ON It enables external program mode.
Query Syntax: [SOURce:]VOLTage:EPRogram[:STATe]?
Return Parameters: OFF | ON
Query Example: VOLT:EPR? It returns the state of external program mode.
6-12

Table of Contents

Related product manuals