Remote Operation
VOLTage:LIMit
Description: This command sets the maximum bounds on the AC rms output voltage value.
Setting a larger output voltage value will cause the output to be clamped to the
LIMit value.
Syntax: [SOURce:]VOLTage:LIMit[:AMPLitude] <NRf+>
Parameters: 0 to 300
*RST Value: 300
Example: VOLT:LIM 130 It sets the AC rms output voltage limit to 130V.
Query Syntax: [SOURce:]VOLTage:LIMit[:AMPLitude]?
Return Parameters: <NR2>
Query Example: VOLT:LIM? It returns the set value of output voltage limit.
VOLTage:RANGe
Description: This command sets the output voltage range of the AC source. Two ranges are
available: 150V and 300V range. When setting output voltage to 150V range, if
the setting of output voltage is greater than 150V, it will be clamped to 150V.
Setting an output voltage range will disable the AUTO range mode.
Syntax: [SOURce:]VOLTage:RANGe <NRf+>
Parameters: 150 | 300
*RST Value: 150
Example: VOLT:RANG 300 It sets the output voltage to 300V range.
Query Syntax: [SOURce:]VOLTage:RANGe?
Return Parameters: <NR1>
Query Example: VOLT:RANG? It returns the voltage output range.
VOLTage:RANGe:AUTO
Description: This command enables or disables the AUTO output voltage range mode. In
AUTO mode, the output voltage must be set as greater than 150 volt, and it
will be switched to 300V range, otherwise the 150V range is selected.
Syntax: [SOURce:]VOLTage:RANGe:AUTO <Boolean>
Parameters: 0 | 1 | OFF | ON
*RST Value: OFF
Example: VOLT:RANG:AUTO ON It enables the AUTO output voltage range mode.
Query Syntax: [SOURce:]VOLTage:RANGe:AUTO?
6-13