Remote Operation
Parameters: None
Return Parameters: <NR1>, <SRD>
Query Example: SYSR:ERR? It returns the next error number and description.
SYSTem:LOCal
Description: This command sets the AC source to local state, which enables the control of front
panel. It can only be used with the RS-232C interface.
Syntax: SYSTem:LOCal
Parameters: None
Example: SYST:LOC It sets the AC source to local state.
SYSTem:REMote
Description: This command sets the ac source to remote state, which disables the control of
front panel except the local key. Pressing the local key while in the remote state
returns the AC source to the local state. It can only be used with the RS-232C
interface.
Syntax: SYSTem:REMote
Parameters: None
Example: SYST:REM It sets the AC source to remote state.
SYSTem:RWLock
Description: This command sets the AC source to remote-lockout state, which disables
the control of front panel, including the local key. It can only be used with
the RS-232C interface.
Syntax: SYSTem:RWLock
Parameters: None
Example: SYST:RWL It sets the AC source to remote-lockout state.
*CLS, Clear Status Command
Description: This command clears all Event Registers summarized in the Status Byte Register
(Standard Event Status Register, Questionable Event Register), and clears the
error queue. If the *CLS command immediately follows a program message
terminator, the output queue and the MAV Summary-Message are also cleared.
Syntax: *CLS
Parameters: None