Remote Operation
Return Parameters: Field 1: Manufacturer
Field 2: Model
Field 3: Serial Number or 0
Field 4: Firmware Level or equivalent
Query Example: *IDN?
Return Example: CHROMA ATE, 6430, 0, 0.00
*OPC, Operation Complete Command
Description: This command causes the AC source to set the OPC bit of Standard Event Status
Register when all pending operations are completed.
Syntax: *OPC
Parameters: None
*OPC?,Operation Complete Query
Description: This query returns an ASCII “1” when all pending operations are completed.
Query Syntax: *OPC?
Parameters: None
Return Parameters: 1
*RST, Reset Command
Description: This command resets the AC source to the following states:
OUTP OFF
CURR:LIMit MAX
FREQ 60
VOLT 0
VOLT:EPR OFF
VOLT:LIM 300
VOLT:RANG 150
VOLT:RANG:AUTO OFF
Syntax: *RST
Parameters: None
6-19