Malfunctions/Maintenance
Replacing the Fuse
Repairs and maintenance
may only be performed by
a specialist. Before working
on the unit, switch o the
power supply and secure it
against being switched on
again! Check that there is no
power owing!
Only use the included
safeguard or a similar
safeguard with the following
specications: T2A / 250 V.
If the mains voltage is switched on and the
controller still does not function or display
anything, then the internal device fuse may
be defective. First nd the external fault
source (e.g. pump), replace it and then
check the device fuse.
To replace the device fuse, open the device
as described under “See “ Wall Installation “
on page 8”, remove the old fuse, check it
and replace if necessary.
Then rst recommission the controller and
check the function of the switch outputs in
manual mode as described in Section 3.2. .
Maintenance
!
In the course of the general
annual maintenance of
your heating system, the
functions of the controller
should also checked by a
specialist and the settings
should be optimized if
necessary.
Performing maintenance:
• Check the date and time See “ Time &
Date “ on page 18
• Assess/check plausibility of statistics
See “ Statistics “ on page 11
• Check the error memory See “
Notications “ on page 11
• Verify/check plausibility of the
current measurement values See “
Measurement values “ on page 10
• Check the switch outputs/consumers
in manual mode See “ Manual “ on
page 12
• Possible optimization of the parameters
setting (only on customers request)