Installation
Connection for FCAW (reverse polarity)
1. Open the door to the machine.
2. Remove the polarity terminal knobs.
3. Set up the polarity (as per Table 3-1 above) by removing the leads from the terminals and reversing
them if necessary. Refer to Figure 3-7.
4. Replace the polarity terminal knobs.
Polarity Terminal
Knobs
Cable to
MIG Torch
(Red Cable)
Cable to
Work Lead
(Black Cable)
Art # A-09008_AB
Figure 3-7: Connection for FCAW (reverse polarity)
NOTE
Ensure that polarity terminal knobs are tightly secured and that there is no connection between
positive and negative terminals.