EasyManua.ls Logo

Circutor Raption Series - Required Equipment for Configuration

Circutor Raption Series
112 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Service Manual 45
Raption
Settings
Each connector (CHA and CCS) has its own protection parameters, so depending on
which one is being used, Bender will need to adjust to the corresponding values. By
default it is configured with CCS settings. However, when a CHAdeMO charging session
is about to start, Mode 4 board sends the values for this connector.
Bender device can be configured manually using its buttons or via software, on RS485
communications.
Check the Annexes to find the configuration steps in case service staff has to do the
settings manually.
When device is configured via software, ask sat@circutor.com to get the necessary files.
Additional function
Bender does not only work as an Isolation Protector. It has a secondary function.
It is measuring the Output Voltage in DC for both connectors and provides these values
to the controller device, Mode 4 board.

Other manuals for Circutor Raption Series

Related product manuals