Service Manual 29
Raption
Item Name Function
1 J1 Power supply connector, 12Vdc
2 J13 Inputs for Emergency, VCC; Lock CCS and Lock CHA
3 J11 Inputs for Clixon, tamper and Isolation Detection
4 J9 Inputs for Tacometer, relay state CHA, Precharge state CCS
5 J10 Inputs for Opto (J) and relays state of CCS
6 J23 Outputs PWM turbines control
7 J4 LEDs lock system
Mode 4 Board
B
Mode 4 board is controlling the communications of the Charging Station with the Electric
vehicle.
Also, most of the alarms like the emergency button, isolation protectors or clixon are
managed by this board.