Raption
34 Service Manual
Mode 3 Charge Controller (A6) is responsible for conducting the Mode 3 communications
and allows charging electrical vehicle as defined by IEC 61851 for AC side.
Communication to the device is only possible via RS485 communications through inputs
1 and 2. The device integrates an Ethernet port, which does not allow connectivity to
TCP/IP networks. It is used for internal use as digital inputs and outputs.
The default configuration modbus address is set at 96 and baud rate is set to 19200bps.
Item Name Function
1 PP- EV Connection Proximity (PP)
2 CP-EV Connection Control Pilot (CP)
3 A- RS-485 BUS Terminal (+)
4 B- RS-485 BUS Terminal (-)
5 A1- Power Supply 12 V
6 A2- Power Supply 0 V
7 RL- Contactor Contactor coil
8 Ground Ground
Mode 3 Device