Service Manual 41
  
Raption 
Backflow diode and Clixon
E
Backflow diode protects the internal components of the Raption from any current that 
could come from the oposite side, from the EV to the Charging Station.
This may occur in case there is a problem balancing the voltages, either on the EV or in 
the Charging Station side.
In order to keep a safe temperature in this zone, it is installed a radiator and a fan.
Additionally, it is installed a Clixon. This component will notify the Mode 4 board in case 
temperature in this zone is above 80ºC. This alarm will generate an error that will stop 
any live charging session and will keep the unit out of service until problem is fixed.
   Model for Raption 50                 Model for Raption 50 HV, Raption 50 EVO  
and Raption 100