P/N 13772-151 45 of 52
Cirrus Design Section 9
SR22T Supplements
System Control
System operation is controlled by five bolster panel switches and three
MFD softkeys:
•Bolster Panel Switches: Metering pump operation and mode
control (flow rate) are controlled by the NORM, HIGH, and MAX
switches. WINDSHLD controls the windshield pump operation.
PUMP BKUP is used in the event of certain system failures.
MFD Softkeys: Tank selection is provided by three MFD softkeys
on the MFD Engine Page. Automatic tank selection is provided
by the default, AUTO mode. While the system is operating, the
fluid quantity in each tank will be passively balanced by
alternating the selected tank using the 3-way control valve.
Mode Control
•NORM controls both pumps to operate quarter-time
intermittently to provide 100% flow rate, i.e. 30 seconds on, 90
seconds off.
•HIGH controls #1 pump to operate continuously to provide
200% flow rate, i.e. two times the normal flow rate.
•MAX controls both pumps to operate continuously for 2 minutes
to provide 400% flow rate, i.e. four times the normal flow rate.
Pump operation then reverts to the system mode selected by
the ICE PROTECT Mode Switch.
•WINDSHLD controls the windshield pump to operate
continuously for approximately 3 seconds.
•PUMP BKUP controls #2 pump to operate continuously to
provide 200% flow rate, i.e. two times the normal flow rate.
When pump backup mode is selected, an alternate circuit by-
passes the Timer Box and supplies power to the #2 metering
pump which in turn operates continuously.
Fluid Tank Control
AUTO: While the system is operating, the fluid quantity in each
tank is passively balanced by the avionics system using the 3-
way control valve and the sensed quantity of each tank.
•LEFT: Ice protection fluid is drawn from the left tank regardless
of sensed quantity.
Original Issue: 02-01-13

Table of Contents

Other manuals for Cirrus SR22T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cirrus SR22T and is the answer not in the manual?

Cirrus SR22T Specifications

General IconGeneral
ManufacturerCirrus Aircraft
EngineContinental TSIO-550-K
Horsepower315 hp
Max Takeoff Weight3, 600 lbs
Service Ceiling25, 000 ft
Cabin Width49 in
Cabin Height50 in
Seating Capacity4
AvionicsCirrus Perspective+ by Garmin
CategorySingle-engine piston aircraft
PropellerHartzell 3-blade composite
Wingspan38 ft 4 in
Length26 ft
Height8 ft 11 in
Maximum Cruise Speed213 KTAS
Fuel Capacity92 gallons
Stall Speed64 knots
Safety FeaturesCirrus Airframe Parachute System (CAPS)
Cruise Speed183 knots

Related product manuals