FINAL DRAFT - CISCO CONFIDENTIAL
4-6
Cisco ONS 15216 EDFA2 Operations Guide
78-16033-01
Chapter 4 Provisioning Using ASH and SNMP
Set Alarm Thresholds
Figure 4-1 ONS 15216 EDFA2 Front Panel
Alarms are reported for the following conditions:
Loss or degradation of electrical power
Laser pump overheating, excessive pump current
Loss or degradation of optical input
Alarms can be connected to a network operations center (NOC) network management system (NMS) via
a network element miscellaneous discrete input and/or office alarm panel/system.
For a full description of alarm threshold command attributes, refer to Chapter 5, SNMP MIB
Installation and Configuration or Chapter 6, ASH Commands.
To display the alarm thresholds, use the snmp table display local cerent15216EdfaCfgGroup
command (Example 4-8). This command returns the current alarm threshold default values.
Example 4-8 Displaying the Alarm Thresholds
ash:hostname:ONS15216 EDFA2> snmp table display local cerent15216EdfaCfgGroup
CLASS CERENT-15216-EDFA-MIB.cerent15216EdfaCfgGroup ::=
{
cerent15216EdfaCfgSaved = false;
cerent15216EdfaLpoutSetpoint = 0;
cerent15216EdfaLpoutDeviation = 200;
cerent15216EdfaLpoutHysteresis = 100;
cerent15216EdfaLOSThreshold = -2600;
cerent15216EdfaLOSHysteresis = 100;
cerent15216EdfaCtmpMin = -5;
cerent15216EdfaCtmpMinHysteresis = 1;
cerent15216EdfaCtmpMax = 65;
cerent15216EdfaCtmpMaxHysteresis = 1;
cerent15216EdfaCLEI = "";
cerent15216EdfaPowerBusMode = duplex;
cerent15216EdfaPowerBusDCVoltageMin = 410;
cerent15216EdfaPowerBusDCVoltageMax = 560;
};
To set the alarm thresholds, use the snmp row set local cerent15216EdfaCfgGroup command. After
this command is entered, the user is prompted to modify each attribute, row by row, until all attributes
are set. Alarm threshold attributes are described in Table 4-1 on page 4-7.
-48V B
RET B
-48V A
RET A
RS-232
(EIA/TIA-232)
LAN port
LAN LEDs
Fiber
output
monitor
port
Power
level
warning
Alarm
out
Fiber
output
port
Status
LEDs
Fiber
input
port
71176
-48V A
R A
POWER
FAIL
LOS
-48V B
R B
CISCO ONS 15216
RS-232
ALARM OUT
LAN

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco 15216 EDFA2 and is the answer not in the manual?

Cisco 15216 EDFA2 Specifications

General IconGeneral
BrandCisco
Model15216 EDFA2
CategoryNetwork Router
LanguageEnglish

Related product manuals