Hardware Installation Guide for Cisco 4000 Series Integrated Services Routers
OL-32185-02
Chapter 3      Install and Connect Cisco 4000 Series ISRs
  Connect WAN, LAN, and Voice Interfaces
Caution To comply with the Telcordia GR-1089 NEBS standard for electromagnetic compatibility and safety, 
connect Gigabit Ethernet ports using RJ-45 connectors for shielded twisted pair cable only to 
intra-building or unexposed wiring or cable. The intra-building cable must be shielded and the shield 
must be grounded at both ends. The intra-building port(s) of the equipment or subassembly must not be 
metallically connected to interfaces that connect to the OSP or its wiring. These interfaces are designed 
for use as intra-building interfaces only (Type 2 or Type 4 ports as described in GR-1089-CORE, Issue 
4) and require isolation from the exposed OSP cabling. The addition of Primary Protectors is not 
sufficient protection in order to connect these interfaces metallically to OSP wiring.
Warning
Never install telephone jacks in wet locations unless the jack is specifically designed for wet 
locations. 
Statement 1036
Warning
Never touch uninsulated telephone wires or terminals unless the telephone line has been 
disconnected at the network interface. 
Statement 1037
Warning
Class 1 laser product. 
Statement 1008